Tavrida Electric | Air Insulated Switchgear
MILE AIS – PRIMARY AND SECONDARY DISTRIBUTION SYSTEMS
Compliance with IEC 62271-200 to perform safer.
MILE is designed to meet the LSC2B-PM AFLR 31,5kA 1s classification as per IEC 62271-200.
The design is fully type tested to IEC 62271-200. The following type tests have been successfully passed:
Short time and peak withstand current on primary circuits
Short time and peak withstand current on earthing circuits
Temperature rise and main circuit impedance
Dielectric test on main and auxiliary circuits
Making and breaking capacity of the circuit breaker within the panel
In addition to IEC 62271-200 requirements, the application of a VCB with MAGNETIC ACTUATORS in MILE provides unique and unrivalled safety features such as remote and safe manual closing of VCB with a palm-held manual generator and the fastest arc fault interruption in less than one cycle.
High operational reliability
The robust enclosure, made of 2mm corrosive resistant hot-dip galvanised metal sheets with reinforced doors and a safety labyrinth allows fast and simple erection.
A rivet nut design provides not only rigidity of construction but also an opportunity to replace metal parts on-site without the use of special tools.
An emergency trip push-button is located in the center of the panel. It has a striking, protruding design protected against accidental operation. The trip button can be quickly located in an emergency.
Large and clearly visible mechanical position indicators located in view of an operator allows for positive operating status identification of the draw-out unit, VCB and earthing switch. Each mechanical indicator changes its status so that it exactly reflects/corresponds to the status of the switching device. Mechanical position indicators are duplicated by electrical auxiliary contacts to provide electrical signals into secondary circuits.
Lockable access to the VCB racking in/out mechanism by a metallic shutter prevents unauthorised operations and interlocks the VCB in the trip position prior to racking a draw-out unit.
An LV plug interlock visually prompts an operator to connect the draw-out unit to secondary circuits before the compartment door is closed.
Accessories, such as door hinges, handlebars, locks and electrical indicators and buttons withstand thousands of operations and guarantee the appearance of a quality
Minimal service checks on site and MILE is designed for a service life of at least 30 years. The VCB, earthing switch and cast resin insulation technology is considered virtually maintenance-free, so the maintenance requirements are only related to periodical checks to ensure the system operates correctly.
Greater Application Versatility
Common design platform for 12, 17,5 and 24kV panels.
Cassette and truck versions are available.
Front or Front and Rear accessibility to the cable compartment
Two sets of CTs and VT cassette placed in VCB or cable compartments.
Panel width can be 600, 750 or 1000mm.